1).載流量不應(yīng)小于負(fù)荷計(jì)算電流;
1). Should not be less than the load calculation of current carrying capacity;
2).滿足機(jī)械強(qiáng)度的要求;
2). To meet the requirement of mechanical strength;
3).自配電變壓器的低壓母線至盧重機(jī)電動(dòng)機(jī)端子的電壓損失,在尖峰電流時(shí),不宜超過額定電壓的15%。
3). The voltage loss from low voltage distribution transformer to Lu heavy machinery motor terminal, the peak current, should not exceed 15% of the rated voltage.
2.少起重機(jī)供電線路的電壓損失,可根據(jù)具體情況采取下列措施:
2 little crane voltage loss of power supply line, the following measures may be adopted according to the specific situation:
1).電源線盡量接至天車滑線的中部;
1). The central power line as far as possible to crane slide wire;
2).采用絕緣式安全滑觸線;
2). The insulation safety sliding contact line;
3).適當(dāng)增大滑觸線截面或增設(shè)輔助導(dǎo)線;
3). Increasing the sliding contact line section or adding the auxiliary conductors;
4).增加滑觸線供電點(diǎn)或分段供電;
4). To increase the sliding contact line power supply or sectional power supply point;
5).增大電源線或軟電纜截面。
5). Increasing the power line or cable section.